Final | 10/13/2014 | 10/13/2014 | 10/13/2014 | P | PASS |
Rock A. Hudson
|
|
|
Corrections made. Garage code 0500. Thank you Phone #: ###-#### Inspection requested via web by daniel bibikov Final ok
|
Final | 10/9/2014 | 10/9/2014 | 10/9/2014 | P | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov 210.51 (D) Bathrooms. In dwelling units, at least one receptacle outlet shall be installed in bathrooms within 900 mm (3 ft) of the outside edge of each basin. The receptacle outlet shall be located on a wall or partition that is adjacent to the basin or basin countertop, located on the countertop, or installed on the side or face of the basin cabinet. 400.8 Uses Not Permitted. Unless specifically permitted in 400.7, flexible cords and cables shall not be used for the following: (1) As a substitute for the fixed wiring of a structure (2) Where run through holes in walls, structural ceilings, suspended ceilings, dropped ceilings, or floors (3) Where run through doorways, windows, or similar openings (4) Where attached to building surfaces.
314.25 Covers and Canopies. In completed installations, each box shall have a cover.
|
Rough-In Permanent Service | 7/29/2014 | 7/29/2014 | 7/29/2014 | P | PASS |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov rough-in house and detached garage, no underground to garage. p/s u/g n ok
|