Permit Information
Permit NumberELE14-02463
StatusFinaled
Name LEADING EDGE ELECTRIC
Site Address 1625 S DIVISION AVE
Project Name 
Customer Number794-6116
ePlanReviewNo
Description
Electrical Permit - New: New dwelling Row House///per Rock Hudson(327) added 10 rooms & A/C
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/28/20154/29/20154/29/2015APASS
DetailsBob Reichert
Request final. Tim ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence ok final
Final2/27/20153/2/20153/2/2015AFAIL
DetailsBob Reichert
Tim ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence called, left correction notice, BCC 50% lamps shall be energy efficient, NEC 110.26 shall provide 3' clear space in front of panel, 250.56 sahll provide 2 ground rods at garage, 410.16 shall provide 12" from edge of luminaire in masrter bedroom to edge of shelf
Final2/26/20152/27/20152/27/2015ANH
DetailsCevyn Recla
Tim. ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence Inspection cancelled from web by: Tim Lawrence
called tim, left message prior to him cancelling that there is no access
Rough-In Permanent Service9/24/20149/25/20149/25/2014PPASS
DetailsRock A. Hudson
Electrical Rough. Tim. ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence Rough in ok cover p/s u/g n ok
Rough-In Permanent Service9/22/20149/23/20149/23/2014PFAIL
DetailsBob Reichert
Electrical Rough/service. Also have conduits that feed detached garages that will be installed in open trench to inspect. Tim ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence called, left correction notice, NEC 300.5 u/g raceway shall be minimum 18" deep, 300.4(A) edge of bored hole shall be 1 1/4" from edge of framing member, 250.86 shall ground metal box, 314.20 outside boxes shall be flush with finished surface, BCC shall provide ground rods at garage, shall change room count on permit to 13 rooms, shall add a/c to permit, talked to contractor, ok to cover u/g but at final shall be sure 4" concrete runs from service at garage to edge of house minimum