Final | 9/29/2014 | 9/29/2014 | 9/29/2014 | P | PASS |
Rock A. Hudson
|
|
|
Ryan is contact. Thanks! Phone #: ###-#### Inspection requested via web by Chris Chesnut Final ok
|
Electrical Rough-In | 9/11/2014 | 9/11/2014 | 9/11/2014 | P | PASS |
Rock A. Hudson
|
|
|
Chris is contact. Thank you Phone #: ###-#### Inspection requested via web by Chris Chesnut Different contracor doing family room ele14-02416 Kitchen remodel rough in ok cover
|
Conference | 9/8/2014 | 9/9/2014 | 9/9/2014 | A | PASS |
Rock A. Hudson
|
|
|
Need direction on what will have to be brought up to code. Please call before to meet inspector at job site. Thanks! Phone #: ###-#### Inspection requested via web by Chris Chesnut Discussed minimum required for kitchen remodel. Contractor to provide wiring for 2 small appliance circuits to old fused panel which will tie in as single circuit until service change is done in future. Main concern 3 flexible cords ran through walls in kitchen area to be removed and minimum outlet spacing to be installed.
|