Final | 1/13/2015 | 1/13/2015 | 1/13/2015 | P | PASS |
Rock A. Hudson
|
|
|
Side gate is open, just need to check for bonding for hot tub. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Final ok
|
Final | 12/18/2014 | 12/19/2014 | 12/19/2014 | A | FAIL |
Rock A. Hudson
|
|
|
Homeowner will be there. Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan Patio cover installed after electrical. 680.26(B)- All fixed metal parts shall be bonded if located within 5' horizontal and 12' vertical of waters edge. Verbal with owner and contractor.
|
Final | 11/5/2014 | 11/5/2014 | 11/5/2014 | P | FAIL |
Rock A. Hudson
|
|
|
If you have any questions, please call Zack ###-####, thank you. Phone #: ###-#### Inspection requested via web by Clay Morgan Devices not installed, hot tub wiring not complete
|
Electrical Rough-In | 11/5/2014 | 11/5/2014 | 11/5/2014 | P | PASS |
Rock A. Hudson
|
|
|
If you have any questions, please call Zack ###-####, thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Garage rough in ok cover
|
Electrical Rough-In | 10/17/2014 | 10/17/2014 | 10/17/2014 | P | FAIL |
Rock A. Hudson
|
|
|
Just having circuit added inspected, please call Jake when you are on your way. Thank you. Phone #: ###-#### Inspection requested via web by Clay Morgan 300.4(A)(1)&(2)- Where NM cable is ran through notched wood or bored hole that does not maintain 1 1/4" from framing surface it shall be protected from physical damage. NM cable shall also be secured 1 1/4" back from framing surface. 310.16 table as per 334.80- #8 NM cable which feeds hot tub rated at 40 amp max, 50 amp breaker installed. 334.30- NM calbe shall be secured with in 12 " of boxes. Recommend service calculation to ensure hot tub does not over load 100 amp service. Please call with results. ###-####
|