Final | 12/1/2014 | 12/2/2014 | 12/2/2014 | A | PASS |
Bob Reichert
|
|
|
call for code Phone #: ###-#### Inspection requested via web by Neal Rumsey ok final
|
Electrical Rough-In | 11/19/2014 | 11/19/2014 | 11/19/2014 | P | PASS |
Bob Reichert
|
|
|
Floor heat in the master bath Phone #: ###-#### Inspection requested via web by Neal Rumsey ok cover floor heat
|
Rough-In Permanent Service | 10/29/2014 | 10/29/2014 | 10/29/2014 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey Corrections made RI OK PS, UG, N OK
|
Electrical Rough-In | 10/27/2014 | 10/28/2014 | 10/28/2014 | A | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey
Spoke to contractor 300.5C(4) Sch 80 PVC for riser where subject to physical damage 300.4A(1) nail plates, edged of bored hole to be 1 1/4" from edge of framing member or protection is required 210.52 E(1) receptacles required_ rear outdoor receptacle required BC 4.05.23 Concealment of work, no soffit inspection performed
|