Final | 11/4/2015 | 11/5/2015 | 11/5/2015 | P | PASS |
Rock A. Hudson
|
|
|
Call 15 minutes before // Brad Phone #: ###-#### All GFCI protective devices in readily accessible locations, Corrections have been made. Final ok
|
Final | 9/11/2015 | 9/14/2015 | 9/14/2015 | P | CANC |
Rock A. Hudson
|
|
|
Brad Phone #: ###-####-please call 15 minutes prior for access
|
Final | 7/17/2015 | 7/21/2015 | 7/21/2015 | P | CANC |
Bob Reichert
|
|
|
would like call ahead; Brad Phone #: ###-####
|
Electrical Rough-In | 7/15/2015 | 7/17/2015 | 7/17/2015 | P | PASS |
Rock A. Hudson
|
|
|
would like call ahead; Brad Phone #: ###-#### 5 new branch circuits, 4 total rooms. Nail plate above panel. 3-way switch needs to be operational at door into master bed as per 210.70. GFCI protection required on all 5 circuits, 2 xmas, 1 jetted tub, 1 garage openers, freezer circuit. rough in ok cover.
|
Electrical Rough-In | 6/30/2015 | 7/1/2015 | 7/1/2015 | A | PASS |
Eric Story
|
|
|
First inspection please, requests before 9AM, Please call ahead for access - Brad Phone #: ###-#### storage room understairs ok cover
|
Electrical Rough-In | 6/29/2015 | 6/30/2015 | 6/30/2015 | P | NH |
Rock A. Hudson
|
|
|
Brad Phone #: ###-#### No answer at door unable to make contact with phone call. Left card
|
Conference | 6/16/2015 | 6/17/2015 | 6/17/2015 | A | DONE |
Rock A. Hudson
|
|
|
Brad Phone #: ###-#### Discussed adding additional rooms to permit, multiwire branch circuits for when rearrange circuits in panel, totally enclosed lamps for storage areas
|
ELE-Request for Extension | 5/6/2015 | 5/7/2015 | 5/7/2015 | A | PASS |
Rock A. Hudson
|
|
|
call with questions - Brad Phone #: ###-#### Extension ok
|
Conference | 11/17/2014 | 11/18/2014 | 11/18/2014 | A | DONE |
Rock A. Hudson
|
|
|
Brad Phone #: ###-#### Discussed if service had rating to add additional circuits if wanted. 20/40 ITE 200 amp with room to twin or quad
|
Conference | 11/7/2014 | 11/10/2014 | 11/10/2014 | A | DONE |
Daryl DeGrange
|
|
|
Brad Phone #: ###-#### Discuss with homeowner electrical requirements for adding freezer branch circuit in garage, surface mount florscent fixtures.
|