Final | 1/29/2015 | 1/30/2015 | 1/30/2015 | A | PASS |
Rex Boyles
|
|
|
Ron Phone #: ###-#### final ok
|
Electrical Rough-In | 1/30/2015 | 1/30/2015 | 1/30/2015 | P | PASS |
Rex Boyles
|
|
|
Ron Phone #: ###-#### corrections made r/i ok
|
Electrical Rough-In | 1/28/2015 | 1/29/2015 | 1/29/2015 | A | FAIL |
Rock A. Hudson
|
|
|
Ron Phone #: ###-#### 314.16- Boxes shall have sufficient size to provide free air space for enclosed conductors. 300.4- Bored holes that do not maintain 1 1/4" shall have nail plates. * Receptacle outlets located in garage shall be above 18" minimum.
|
Electrical Rough-In | 1/20/2015 | 1/20/2015 | 1/20/2015 | P | CANC |
Cevyn Recla
|
|
|
Ron Phone #: ###-#### wrong inspection, see conference
|
Conference | 1/20/2015 | 1/20/2015 | 1/20/2015 | P | DONE |
Cevyn Recla
|
|
|
Ron Phone #: ###-#### Discussion of requirements for adding receptacles in garage. GFI protection requirements, nail plates, etc.
|