Final | 12/5/2014 | 12/8/2014 | 12/8/2014 | P | PASS |
Cevyn Recla
|
|
|
16 solar panels. AC micro-inverter system. No DC voltage. M250 Enphase Micro-Inverters, CSA, IEEE-1547, and UL-1741 listed and 270 watt Suniva panels, ETL listed A single home run, in conduit, is ran from solar array to the knife switch, located next to meter base on west side of home in back yard. From the knife switch to breaker in main panel, at the bottom of the busing, opposite the feeder lugs. The solar breaker and the knife switch are clearly marked for solar, and the circuit number identified in the knife switch. The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service electrode under the main panel.
The main panel is in the back yard, so give the homeowner a call at 949.6005 for access. If homeowner is not able to be home, call me and I can meet you there.
Thanks guys Phone #: ###-#### Inspection requested via web by Ryan King left message for contractor FInal OK
|