Final | 12/24/2014 | 12/26/2014 | 12/26/2014 | A | PASS |
Cevyn Recla
|
|
|
Jadd Phone #: ###-#### corrections made, final OK
|
Final | 12/11/2014 | 12/11/2014 | 12/11/2014 | P | FAIL |
Cevyn Recla
|
|
|
Please call ahead, homeowner not home all day - Brady Phone #: ###-#### More conference than inspection all breakers need to be labeled arc fault protection required for smoke detectors and bedrooms need all switch and outlet plates installed need service light for water heater a/c wiring needs replaced, aluminum flex and nm cable not allwed outdoors, max breaker size allowed is 25 amp
|