Final | 1/9/2015 | 1/14/2015 | 1/14/2015 | P | PASS |
Cevyn Recla
|
|
|
24 solar panels. AC micro-inverter system. No DC voltage. Enphase M250 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed. And 270 watt Suniva panels, ETL listed.
A single home run, in conduit, is ran from the solar array to the knife switch, located next to meter base on south side of home. From the knife switch to breaker in main panel, at the top of the busing, opposite the feeder lugs. The solar breaker and the knife switch are clearly marked for solar, and the circuit numbers identified in the knife switch and on the panel schedule.
The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service electrode under the main panel.
The main panel is located outside, on the south corner, and there is no fences or pets so your all clear for access.
I am aware that Boise Inspectors want a rough-in inspection on these as of the new year, however this particular job was done electrically a couple weeks ago, and was only just connected to the panels. As always, give me a call if ya need anything -
Thanks guys Phone #: ###-#### Inspection requested via web by Ryan King Final OK
|