Final | 5/28/2015 | 5/29/2015 | 5/29/2015 | A | PASS |
Rex Boyles
|
|
|
Call to entrance info // Jose Phone #: ###-#### final ok
|
Electrical Rough-In | 1/28/2015 | 1/29/2015 | 1/29/2015 | A | PASS |
Rex Boyles
|
|
|
Jose Phone #: ###-#### corrections made r/i ok
|
Electrical Rough-In | 1/27/2015 | 1/28/2015 | 1/28/2015 | A | FAIL |
Rex Boyles
|
|
|
Call for access - Jose Phone #: ###-#### 300.4(A)(1)--bored holes in wood members shall be minimum 11/4" to edge of member. 334.30- secure NM cable within 12" of box. (conductors outside of box in liv.rm recept.
|
Permanent Service | 1/28/2015 | 1/28/2015 | 1/28/2015 | P | PASS |
Rex Boyles
|
|
|
Call for access - Jose Phone #: ###-#### p/s o/h rec ok
|