Final | 4/23/2015 | 4/24/2015 | 4/24/2015 | A | PASS |
Rex Boyles
|
|
|
The correction from the previous inspection has been corrected, any questions please let me know, thx, TW ACCESS CODE is 0802, (the box is on the left side on the house by the AC unit) Phone #: ###-#### Inspection requested via web by Stephen Kren corrections made final ok
|
Permanent Service | 4/7/2015 | 4/8/2015 | 4/8/2015 | A | PASS |
Rex Boyles
|
|
|
The lock box is on the AC disconnect on the left side of the house, the code is 0802, all corrections have been made, any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren p/s u/g rec ok Note: nm cable in garage unfinished and hot and cold jumper on water heater still needed prior to final inspection
|
Permanent Service | 1/28/2015 | 1/29/2015 | 1/29/2015 | A | FAIL |
Rock A. Hudson
|
|
|
There hasn''t been a meter at this location for over a year, Idaho Power is requiring an inspection of the service before powering. The ACCESS CODE is 0802 any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren 250.50- All grounding electrodes present shall be used. Complete bonding of metal water pipe at water heater. 334.30 NM cable shall be secured within 12" above panel. 334.116- Outer sheath shall be present and enter box by minimum of 1/4". Remove branch circuit to 240 volt receptacle in garage. * Repair flex at furnace.
|