Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberELE15-00264
StatusFinaled
Name S K ELECTRIC
Site Address 1577 W SILVER CREST DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - New: wiring of new house
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/2/20157/2/20157/2/2015APASS
DetailsEric Story
please call if you have any questions home owner is on site he has moved some items in garage and will move anything that you need moved. Phone #: ###-#### Inspection requested via web by Shaun Kirkman house final ok
Electrical Rough-In6/26/20156/26/20156/26/2015PPASS
DetailsEric Story
floor heat in master bath Phone #: ###-#### Inspection requested via web by Shaun Kirkman master bath floor ht rough-in ok cover
Rough-In Permanent Service2/18/20152/18/20152/18/2015PPASS
DetailsCevyn Recla
Corrections have been made Phone #: ###-#### Inspection requested via web by Shaun Kirkman
corrections made, RI OK, PS, UG, N, OK
Rough-In Permanent Service2/12/20152/12/20152/12/2015AFAIL
DetailsCevyn Recla
Gate code is #1599 Phone #: ###-#### Inspection requested via web by Shaun Kirkman
Fire boxes in soffits need to be sealed and fire caulked at penetrations.
No permit is pulled on solar installation
110.12 A unsused openings shall be closed
BCC 4.05.25 Rough in inspectio required and shall include all mechanical installations, ground wire for solar?
360.12 FMT not permitted in runs over 6 foot in length
called Shaun
Evengreen Tech is doing solar and will be permitting their own