Final | 6/17/2015 | 6/17/2015 | 6/17/2015 | P | PASS |
Bob Reichert
|
|
|
Please give 30 minutes notice if possible Phone #: ###-#### Inspection requested via web by TOM BICANDI corrections made, ok final
|
Final | 6/3/2015 | 6/4/2015 | 6/4/2015 | A | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI called, left message, told to fix receptacles and face plates in kitchen to get then to be flush
|
Rough-In Permanent Service | 3/23/2015 | 3/24/2015 | 3/24/2015 | A | PASS |
Rex Boyles
|
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI r/i ok (look for upst. floor receptacle at final) p/s u/g n ok
|
Rough-In Permanent Service | 3/22/2015 | 3/23/2015 | 3/23/2015 | A | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI called, left correction notice, BCC shall post ESC card, shall post address, shall not cover wiring prior to inspection, 250.24 and 250.64(C) grounding electrode shall be continuous, 334.23 shall protect nm cable within 6' of attic access, 210.70 shall provide light and switch under stairs5tf
|