Final | 8/20/2015 | 8/20/2015 | 8/20/2015 | P | PASS |
Rock A. Hudson
|
|
|
This permit cover rough in and permanent service only. Trim out permit ELE15-02633. Portion this permit covers Final ok
|
Final | 8/17/2015 | 8/18/2015 | 8/18/2015 | A | FAIL |
Rock A. Hudson
|
|
|
Robyn Phone #: ###-#### 210.52(C)(5)- Receptacle outlets that serve counter top shall be located on ar above but not more than 20" above counter top served. 314.20- In wall of tile if box is more than 1/4" recessed in wall a plaster ring or extention ring shall be installed. 334.40- NM cable hanging from soffit shall terminate in a box. 406.9(A)- All 15 or 20 amp receptacle outlets installed outdoors shall be weather resistant type. 406.12- All receptacle outlets installed in or on dwelling unit shall be tamper resistant type. 408.4- Circuit directory shall be completed. 422.30- Appliances shall have a disconnecting means. Water heater and dishwasher shall have a disconnect or lock-out. Called contractor with list of corrections he stated he did not finish job. Informed home owner a permit shall be pulled for trim out of job.
|
Permanent Service | 5/1/2015 | 5/1/2015 | 5/1/2015 | P | PASS |
Rex Boyles
|
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks p/s u/g n ok
|
Final | 4/16/2015 | 4/16/2015 | 4/16/2015 | P | CANC |
Rex Boyles
|
|
|
Panel is labeled. Ready for final Phone #: ###-#### Inspection requested via web by Jason Wicks accidently called in wrong permit
|
Electrical Rough-In | 4/15/2015 | 4/15/2015 | 4/15/2015 | P | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks corrections made, partial ri ok, need to see back wall at service area, add receptacle by closet
|
Electrical Rough-In | 4/15/2015 | 4/15/2015 | 4/15/2015 | A | FAIL |
Rex Boyles
|
|
|
Partial rough in. Everything except the back wall where service will be set. Owner talking with idaho power to see if service can be brought in from underground. Phone #: ###-#### Inspection requested via web by Jason Wicks 300.4=11/4" required from edge of stud to bored hole or use nailplates. 210.52(E)(1)-for a family dwelling at least one receptacle outlet readilly accessable fromgrade shall be installed at front and back of dwelling. 210 70(A)(2)(b)-in dwelling units at least one wall switch controlled lighting outlet shall be installed to provide illumination on the exterior side of outdoor entrances or exits @ grade level.
|