Final | 8/26/2015 | 8/27/2015 | 8/27/2015 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey corrections made, ok final
|
Final | 8/26/2015 | 8/26/2015 | 8/26/2015 | A | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey called, left correction notice, NEC 210.63 sh-all provide receptacle within 25' of a/c- 2 places, 210.52(A)(1) no point along floor line shall be over 6' from receptacle-lower slider, 406.9 shall install w/p receptace and in-use cover on patio
|
Final | 8/24/2015 | 8/25/2015 | 8/25/2015 | P | NR |
Bob Reichert
|
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey called, painters masked baseboards at outlet height, will need to inspect main floor, check downstairs outlet by sliding door and garage outlets rest ok
|
Rough-In Permanent Service | 5/7/2015 | 5/8/2015 | 5/8/2015 | A | PASS |
Rex Boyles
|
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey r/i ok p/s u/g n ok
|