Permit Information
Permit NumberELE15-01337
StatusFinaled
Name ENTERPRISE ELECTRIC
Site Address 200 N 3RD ST Unit: 601
Project NameImperial Plaza Condo
Customer Numberwo #10191
ePlanReviewNo
Description
Addition: Small remodel
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/10/20157/13/20157/13/2015APASS
DetailsRex Boyles
Final inspection. Please contact Alex with any questions Phone #: ###-#### Inspection requested via web by Clint Tate corrections made final ok
Final7/10/20157/10/20157/10/2015PFAIL
DetailsRex Boyles
Final inspection. Please contact Alex with any questions Phone #: ###-#### Inspection requested via web by Clint Tate 210.12 AFCI required in all outlets. 210.8(B)(5)-GFCI required within 6 foot of sinks
Final6/29/20156/30/20156/30/2015PNR
DetailsRex Boyles
Contact is Alex, he would like to meet you onsite for inspection. Phone #: ###-#### Inspection requested via web by Clint Tate kitchen cabinets not complete. Remove millwork in front of loadcenter -NEC 110.26(A)(1)- 36" standing room required in front of loadcenter.210.8- GFCI protection required on all 120volt receptacles in kitchen.
Electrical Rough-In5/8/20155/8/20155/8/2015PPASS
DetailsRex Boyles
Phone #: ###-#### Inspection requested via web by Clint Tate correction done, rough-in ok cover
Rough-In Permanent Service5/7/20155/7/20155/7/2015PFAIL
DetailsDaryl DeGrange
Any time after 11:30. Please contact Alex with any questions ###-#### Phone #: ###-#### Inspection requested via web by Clint Tate NEC 210.52 Receptacle spacing(bedroom) NEC 330.12(1) MC install where subject to physical damage.NEC 330.30 Securing within 12 in. of everybox