Final | 6/5/2015 | 6/8/2015 | 6/8/2015 | A | PASS |
Eric Story
|
|
|
AC micro-inverter system. No DC voltage. Enphase M250 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed. Ironridge Integrated Grounding System mid clamps, bonding straps and bonding lugs. And 270 watt Suniva panels, ETL listed.
A single home run, in metal conduit, is ran from the solar array to the knife switch, located on the front of the house, directly under the solar array. From the knife switch to the breaker in sub panel, located in the mechanical room behind the wall where the knife switch is mounted. The solar breaker and the knife switch are permanently marked for solar, and the circuit numbers identified in the knife switch and on the panel schedule.
The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service grounding electrode in the same sub panel.