Final | 10/8/2015 | 10/9/2015 | 10/9/2015 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Thomas Jenkins Final ok
|
Electrical Rough-In | 10/1/2015 | 10/2/2015 | 10/2/2015 | A | PASS |
Rock A. Hudson
|
|
|
Rough in of serving line wall. Phone #: ###-#### Inspection requested via web by Thomas Jenkins Prefab wall and 1/2 wall rough in ok cover
|
Permanent Service | 10/1/2015 | 10/2/2015 | 10/2/2015 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Thomas Jenkins House panel #1 p/s u/g n ok
|
Rough-In Permanent Service | 9/28/2015 | 9/29/2015 | 9/29/2015 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Thomas Jenkins Service rough in ok p/s u/g n ok
|
Rough-In Permanent Service | 9/28/2015 | 9/28/2015 | 9/28/2015 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Thomas Jenkins Grounding electrode system consists of ground rod, concrete encased, and underground water pipe all bonded. 600 amp 120 208 volt service. 110.24- Available fault current shall be posted with date calculated prior to service hook up.
|
Electrical Rough-In | 9/22/2015 | 9/23/2015 | 9/23/2015 | A | PASS |
Rock A. Hudson
|
|
|
Ceiling cover Phone #: ###-#### Inspection requested via web by Thomas Jenkins Grid rough in ok cover
|
Electrical Rough-In | 9/23/2015 | 9/23/2015 | 9/23/2015 | P | FAIL |
Rock A. Hudson
|
|
|
Ceiling cover Phone #: ###-#### Inspection requested via web by Thomas Jenkins 314.16- Boxes shall be of an approved size to provide free space for all enclosed conductors. Prefab wall behind cook station.
|
Electrical Rough-In | 8/31/2015 | 8/31/2015 | 8/31/2015 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Thomas Jenkins Show window receptacles installed. Perimeter wall rough in ok cover
|
Electrical Rough-In | 8/25/2015 | 8/26/2015 | 8/26/2015 | A | PART |
Rock A. Hudson
|
|
|
Wall inspection Phone #: ###-#### Inspection requested via web by Thomas Jenkins 210.62- At least one 125 volt 15 or 20 amp rated receptacle outlet shall be installed within 18" of top of show window for each 12 linear ft. or major fraction thereof of show window area measured horizontally. Interior walls only rough in ok cover
|
Electrical Rough-In | 8/24/2015 | 8/25/2015 | 8/25/2015 | A | PASS |
Rock A. Hudson
|
|
|
Inspection for soffit Phone #: ###-#### Inspection requested via web by Thomas Jenkins Soffits and hardlid and 1 side demizing wall rough in ok cover
|
Electrical Rough-In | 8/13/2015 | 8/13/2015 | 8/13/2015 | P | PASS |
Rock A. Hudson
|
|
|
Under slave conduits Phone #: ###-#### Inspection requested via web by Thomas Jenkins Under slab rough in ok cover
|
Electrical Rough-In | 8/10/2015 | 8/10/2015 | 8/10/2015 | P | CANC |
Rock A. Hudson
|
|
|
Underground under slab Phone #: ###-#### >> Inspection requested via web by Thomas Jenkins Inspection cancelled from web by: Thomas Jenkins
|