Permit Information
Permit NumberELE15-02720
StatusFinaled
Name I SQUARED INC
Site Address 2007 N 8TH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: Replace fire damaged electrical in basement
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final11/20/201511/20/201511/20/2015PPASS
DetailsRex Boyles
Lockbox at backdoor 4888 Phone #: ###-#### Inspection requested via web by Lars Johnson corrections made final ok
Final11/18/201511/19/201511/19/2015AFAIL
DetailsEric Story
Lockbox at backdoor 4888 Phone #: ###-#### Inspection requested via web by Lars Johnson210.8 receptacles located within 6' of the edge of a sink shall have GFCI protection 210.8 (5) receptacles in a unfinished basement shall have GFCI protection 210.12 all bedrooms shall have AFCI protection
Electrical Rough-In8/26/20158/27/20158/27/2015APASS
DetailsEric Story
Lockbox next to main service by back door. Code 4888. No dogs and no one livong there. Phone #: ###-#### Inspection requested via web by Lars Johnson basement rough-in ok cover