Final | 9/28/2015 | 9/29/2015 | 9/29/2015 | A | PASS |
Rock A. Hudson
|
|
|
This was a Saturday install, requested by the customer. It''s a small system that only took a few hours on Saturday, so I wasn''t able to schedule the rough-in inspection that is used for the listing check of the panels and inverters. However the listing specs are included in the building permit packet that is required on site.
12 solar panels. AC micro-inverter system. No DC voltage. Enphase M250 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed. Ironridge Integrated Grounding System mid clamps, bonding straps and bonding lugs. And 280 watt LG panels, ETL listed.
A single home run, in metal conduit, is ran from the solar array to the knife switch, located next to meter base. From the knife switch to breaker in main panel, at the top bottom of the busing, opposite the feeder lugs. The solar breaker and the knife switch are permanently marked for solar with engraved label plates, and the circuit numbers identified in the knife switch and on the panel schedule.
The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service ground in the main panel.
The main panel is in the garage, so give the homeowner a call for access at 253.224.7624
Thanks guys, Ryan King Phone #: ###-#### Inspection requested via web by Ryan King Final ok
|
Electrical Rough-In | 9/29/2015 | 9/29/2015 | 9/29/2015 | P | PASS |
Rock A. Hudson
|
|
|
This was a Saturday install, requested by the customer. It''s a small system that only took a few hours on Saturday, so I wasn''t able to schedule the rough-in inspection that is used for the listing check of the panels and inverters. However the listing specs are included in the building permit packet that is required on site.
12 solar panels. AC micro-inverter system. No DC voltage. Enphase M250 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed. Ironridge Integrated Grounding System mid clamps, bonding straps and bonding lugs. And 280 watt LG panels, ETL listed.
A single home run, in metal conduit, is ran from the solar array to the knife switch, located next to meter base. From the knife switch to breaker in main panel, at the top bottom of the busing, opposite the feeder lugs. The solar breaker and the knife switch are permanently marked for solar with engraved label plates, and the circuit numbers identified in the knife switch and on the panel schedule.
The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service ground in the main panel.
The main panel is in the garage, so give the homeowner a call for access at 253.224.7624
Thanks guys, Ryan King Phone #: ###-#### Inspection requested via web by Ryan King Listing confirmed. rough in ok
|