Permit Information
Permit NumberELE15-03217
StatusFinaled
Name GOLDEN ELECTRIC
Site Address 2621 N 30TH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Addition: Remodel of existing residence to include new service and wiring throughout
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/1/20162/2/20162/2/2016APASS
DetailsEric Story
Correction notice has been finished

Phone #: ###-#### Inspection requested via web by John Harvey corrections fixed final ok
Final2/1/20162/1/20162/1/2016PFAIL
DetailsEric Story
John is on site Phone #: ###-#### Inspection requested via web by John Harvey 406.4 (5) tamper resistant receptaces required(master bath) 406.5 receptacle mounting shall be secured 406.9 receptacles intalled in a wet location shall be rated 422.31 permanently installed appliances shall a means of lock out trim out buried receptacles
Rough-In Permanent Service1/20/20161/20/20161/21/2016PPASS
DetailsEric Story
James is on site Phone #: ###-#### Inspection requested via web by John Harvey rough-in ok p/s o/h rec ok
Electrical Rough-In1/5/20161/5/20161/5/2016PPASS
DetailsEric Story
House is open. Master floor heat rough in only

Thanks Phone #: ###-#### Inspection requested via web by John Harvey master bath floor heat ok cover
Electrical Rough-In10/6/201510/7/201510/7/2015APASS
DetailsEric Story
Corrections are made. Three electrical boxes added and stapling corrected.

Call Tim if any issues. John is out of town right now. Thanks Phone #: ###-#### Inspection requested via web by John Harvey corrections fixed rough-in ok cover
Electrical Rough-In10/6/201510/6/201510/6/2015PFAIL
DetailsEric Story
John is currently out of town. Please call general contractor Tim if any issues

Rough in only of residence Meter will be set on garage at a later date.


Phone #: ###-#### Inspection requested via web by John Harvey 210.52 (2) wall space greater then 24" requires a receptacle aswell as master bed entry if a hall longer then 10' requires a receptacle 334.30 NM cable shall be supported with 12" of a box and shall not be stapled on edge