Final | 12/29/2015 | 12/30/2015 | 12/30/2015 | A | PASS |
Rock A. Hudson
|
|
|
Call for access code Thanks, Greg Phone #: ###-#### Inspection requested via web by Greg Idsinga Final ok
|
Final | 12/28/2015 | 12/29/2015 | 12/29/2015 | A | FAIL |
Rock A. Hudson
|
|
|
Call before you go for the code. Phone #: ###-#### Inspection requested via web by Greg Idsinga 210.8(B)(5)- All 120 volt receptacle outlets installed with in 6' of a sink shall have GFCI protection. 210.62- At least one 120 volt single phase 15 or 20 amp receptacle outlets shall be installed for each show window 6' or wider on store front.
|
Electrical Rough-In | 12/22/2015 | 12/22/2015 | 12/22/2015 | P | PASS |
Eric Story
|
|
|
Counter wall inspect Phone #: ###-#### Inspection requested via web by Greg Idsinga counter area ok cover
|
Electrical Rough-In | 12/3/2015 | 12/4/2015 | 12/4/2015 | A | PASS |
Bob Reichert
|
|
|
Grid inspect. Call for door code Phone #: ###-#### Inspection requested via web by Greg Idsinga ok cover ceiling
|
Electrical Rough-In | 11/2/2015 | 11/2/2015 | 11/2/2015 | A | PASS |
Rock A. Hudson
|
|
|
Wall and bathroom rough in. Call if the door is locked and I will get you the code. Thanks, Greg. Phone #: ###-#### Inspection requested via web by Greg Idsinga Called and had Carlos assign to BLD15-03578. 2 large LBs and 2 j-boxes under left LB shall remain accessible. Bathroom wall and hard lid rough in ok cover
|