Permit Information
Permit NumberELE15-03691
StatusFinaled
Name DAVID MCCLELLAN CONTRACTING
Site Address 1512 E BOISE AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: Completely rewire 1/2 a duplex and upgrade meter bases & panels after fire.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/14/20163/14/20163/14/2016PPASS
DetailsRex Boyles
Thank you
Please call ###-#### 15 to 30 minutes prior 2 inspection. Alan will come unlock
The door Phone #: ###-#### Inspection requested via web by David McClellan corrections made final ok
Final3/12/20163/14/20163/14/2016AFAIL
DetailsRex Boyles
Please call Alan Queen (homeowner) 15-30 minutes prior to inspection to give him time to get there to open door for inspector. His number is ###-#### Phone #: ###-#### Inspection requested via web by David McClellan 422.31-lockoff on water heater, fire caulk all holes in back, top and bottom of loadcenter in hot wall between garage and house
Electrical Rough-In12/21/201512/21/201512/21/2015APASS
DetailsRex Boyles
Call for key code Phone #: ###-#### Inspection requested via web by David McClellan r/i ok David said he will wrap loadcenter in hot wall between garage and house before building inspection
Rough-In Permanent Service11/29/201511/30/201511/30/2015ACANC
DetailsEric Story
Need power restored as soon as possible for construction. Do I need to get available fault current from Idaho Power? Phone #: ###-#### Inspection requested via web by David just needed p/s
Permanent Service11/30/201511/30/201511/30/2015PPASS
DetailsEric Story
Need power restored as soon as possible for construction. Do I need to get available fault current from Idaho Power? Phone #: ###-#### Inspection requested via web by David McClellan p/s o/h rec ok
Temporary Service11/25/201511/27/201511/27/2015AFAIL
DetailsRex Boyles
Inspection requested via web by David McClellan as per 230.24 exhibit 230.20 in hand book 18" minimum required from bottom of drip loop to roof. Tried to call but ###-#### not in service. I think calling for perm. service for each unit would work here. please list address on each main disconnect first. thanks
Conference11/12/201511/16/201511/16/2015ADONE
DetailsRex Boyles
Would like to consult w/inspector to determine some necessary requirements on this duplex. Thank you. Phone #: ###-#### Inspection requested via web by David McClellan discuss requirements for half of duplex not affected by fire.Since new service is being installed new subpanel and subfeed and new feeds to dryer and range will be required to satisfy 250.140. If no changes are done to branch circuitry or devices they can be left alone.