Final | 3/14/2016 | 3/14/2016 | 3/14/2016 | P | PASS |
Rex Boyles
|
|
|
Thank you Please call ###-#### 15 to 30 minutes prior 2 inspection. Alan will come unlock The door Phone #: ###-#### Inspection requested via web by David McClellan corrections made final ok
|
Final | 3/12/2016 | 3/14/2016 | 3/14/2016 | A | FAIL |
Rex Boyles
|
|
|
Please call Alan Queen (homeowner) 15-30 minutes prior to inspection to give him time to get there to open door for inspector. His number is ###-#### Phone #: ###-#### Inspection requested via web by David McClellan 422.31-lockoff on water heater, fire caulk all holes in back, top and bottom of loadcenter in hot wall between garage and house
|
Electrical Rough-In | 12/21/2015 | 12/21/2015 | 12/21/2015 | A | PASS |
Rex Boyles
|
|
|
Call for key code Phone #: ###-#### Inspection requested via web by David McClellan r/i ok David said he will wrap loadcenter in hot wall between garage and house before building inspection
|
Rough-In Permanent Service | 11/29/2015 | 11/30/2015 | 11/30/2015 | A | CANC |
Eric Story
|
|
|
Need power restored as soon as possible for construction. Do I need to get available fault current from Idaho Power? Phone #: ###-#### Inspection requested via web by David just needed p/s
|
Permanent Service | 11/30/2015 | 11/30/2015 | 11/30/2015 | P | PASS |
Eric Story
|
|
|
Need power restored as soon as possible for construction. Do I need to get available fault current from Idaho Power? Phone #: ###-#### Inspection requested via web by David McClellan p/s o/h rec ok
|
Temporary Service | 11/25/2015 | 11/27/2015 | 11/27/2015 | A | FAIL |
Rex Boyles
|
|
|
Inspection requested via web by David McClellan as per 230.24 exhibit 230.20 in hand book 18" minimum required from bottom of drip loop to roof. Tried to call but ###-#### not in service. I think calling for perm. service for each unit would work here. please list address on each main disconnect first. thanks
|
Conference | 11/12/2015 | 11/16/2015 | 11/16/2015 | A | DONE |
Rex Boyles
|
|
|
Would like to consult w/inspector to determine some necessary requirements on this duplex. Thank you. Phone #: ###-#### Inspection requested via web by David McClellan discuss requirements for half of duplex not affected by fire.Since new service is being installed new subpanel and subfeed and new feeds to dryer and range will be required to satisfy 250.140. If no changes are done to branch circuitry or devices they can be left alone.
|