Permit Information
Permit NumberELE15-03755
StatusFinaled
Name HIGH GROUND ELECTRIC & CONSTRUCTION
Site Address 1808 N 16TH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: 200 amp overhead service with main breaker
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled  4/5/2016 DONE
On 3-21
Final3/18/20163/21/20163/21/2016APASS
DetailsEric Story
Phone #: ###-#### Inspection requested via web by Kendra Lanham correations fixed final ok
Final3/17/20163/18/20163/18/2016AFAIL
DetailsEric Story
Thank you Phone #: ###-#### Inspection requested via web by Kendra Lanham 422.31 lockout required for fixed appliances(dishwasher) 210.12 AFCI protection required for all bedrooms
Final3/17/20163/17/20163/17/2016PCANC
DetailsEric Story
Need final this morning if possible Phone #: ###-#### Inspection requested via web by Kendra Lanham not ready at this time
Rough-In Permanent Service12/9/201512/9/201512/9/2015PCANC
DetailsEric Story
Kendra Phone #: ###-#### just needed p/s
Permanent Service12/9/201512/9/201512/9/2015PPASS
DetailsEric Story
Kendra Phone #: ###-#### p/s o/h rec ok
Permanent Service12/8/201512/9/201512/9/2015AFAIL
DetailsEric Story
200 amp overhead service. Will track wiring as they go. Phone #: ###-#### Inspection requested via web by Kendra Lanham 250.53 (a)(2) supplemental ground ing electrode required 360.10 FMT only can be used in a dry location
Electrical Rough-In11/24/201511/24/201511/24/2015PPASS
DetailsEric Story
Phone #: ###-#### Inspection requested via web by Kendra Lanham rough-in ok cover
Rough-In Permanent Service11/23/201511/24/201511/24/2015ACANC
DetailsEric Story
Phone #: ###-#### Inspection requested via web by Kendra Lanham needed rough-in
Rough-In Permanent Service11/19/201511/23/201511/23/2015PFAIL
DetailsEric Story
Phone #: ###-#### Inspection requested via web by Kendra Lanham 300.4 bored holes within 1 1/4 from face of framing member shall be protected from physical damage
Rough-In Permanent Service11/18/201511/20/201511/19/2015ACANC
DetailsEric Story
Phone #: ###-#### >> Inspection requested via web by Kendra Lanham Inspection cancelled from web by: Kendra Lanham