Final | 5/16/2016 | 5/16/2016 | 5/16/2016 | P | PASS |
James Ady
|
|
|
Final for the house and shop please. Phone #: ###-#### Inspection requested via web by Greg Idsinga Final ok
|
Final | 5/5/2016 | 5/6/2016 | 5/5/2016 | A | CANC |
Eric Story
|
|
|
Final the house and the shop. Thanks Phone #: ###-#### >> Inspection requested via web by Greg Idsinga Inspection cancelled from web by: Greg Idsinga
|
Electrical Rough-In | 3/8/2016 | 3/8/2016 | 3/8/2016 | P | PASS |
Bob Reichert
|
|
|
Garage is roughed in. Phone #: ###-#### Inspection requested via web by Greg Idsinga garage only ok cover inside, will do p/s and u/g later
|
Electrical Rough-In | 1/28/2016 | 1/29/2016 | 1/29/2016 | A | PASS |
Rex Boyles
|
|
|
Phone #: ###-#### Inspection requested via web by Greg Idsinga corrections made r/i ok
|
Electrical Rough-In | 1/27/2016 | 1/28/2016 | 1/28/2016 | A | FAIL |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by Greg Idsinga 334.30 type nm cable shall be supported every 4 1/2' 300.4 nailplates required where bored hole is 1 1/4 of hole 210.52 (a)(1) receptacle spacing shall not be greater then 12' measured alon wall line
|