Final | 5/26/2016 | 5/27/2016 | 5/27/2016 | A | PASS |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson EC blank fixture box above bathtub. correcions fixed final ok
|
Final | 5/25/2016 | 5/26/2016 | 5/26/2016 | A | FAIL |
Eric Story
|
|
|
Garage code 6776 Phone #: ###-#### Inspection requested via web by Therrin Robertson 410.10(d) no parts of luminaire shall be within 8' vertically of a bathtub 210.8 all receptacles within 6' of a basin shall have GFCI protection (receptacle accross from drinking fountain needs to protected)
|
Rough-In Permanent Service | 1/31/2016 | 2/1/2016 | 2/1/2016 | A | PASS |
Daryl DeGrange
|
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson rough-in ok cover p/s u/g n ok
|
Electrical Rough-In | 1/29/2016 | 1/29/2016 | 1/29/2016 | P | PASS |
Rock A. Hudson
|
|
|
Soffits Phone #: ###-#### Inspection requested via web by Therrin Robertson Soffits only rough in ok cover
|