Final | 5/24/2016 | 5/24/2016 | 5/24/2016 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Inspection requested via web by kevin blackmon corrections made, ok final
|
Final | 5/22/2016 | 5/23/2016 | 5/23/2016 | A | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### Inspection requested via web by kevin blackmon called, left correction notice, NEC 408.4 (A) shall complete circuit directory, 210.52(E)(3) shall install receptacle on deck, 210.70 (A)(2)(c) shall provide switched lighting at top and bottom of stairs
|
Electrical Rough-In | 4/26/2016 | 4/27/2016 | 4/27/2016 | A | PASS |
Bob Reichert
|
|
|
Floor heat Phone #: ###-#### Inspection requested via web by kevin blackmon corrections made, ok cover floor heat
|
Electrical Rough-In | 4/22/2016 | 4/25/2016 | 4/25/2016 | A | FAIL |
Bob Reichert
|
|
|
Floor heat Phone #: ###-#### Inspection requested via web by kevin blackmon called, left correction notice, NEC 110.3(B) shall install heat cable per manufacturers instructions, min 3" from wall
|
Rough-In Permanent Service | 3/2/2016 | 3/2/2016 | 3/2/2016 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Inspection requested via web by kevin blackmon ri ok, p/s u/g n ok
|