Final | 5/23/2016 | 5/24/2016 | 5/24/2016 | A | PASS |
Daryl DeGrange
|
|
|
Garage code is 0500 or 6622 Phone #: ###-#### Inspection requested via web by TOM BICANDI final ok
|
Rough-In Permanent Service | 3/25/2016 | 3/25/2016 | 3/25/2016 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI Rough in ok cover p/s u/g n ok
|
Rough-In Permanent Service | 3/24/2016 | 3/24/2016 | 3/24/2016 | P | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI 300.15 Boxes shall be installed on front lights. 314.17- NM cable sheath shall enter with 1/4" min inside box. fireplace. connecters on flexible non metallic conduit for furnace and house fan. Empty boxes in garage and up beds
|