Final | 6/9/2016 | 6/10/2016 | 6/10/2016 | A | PASS |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI Final ok
|
Rough-In Permanent Service | 4/1/2016 | 4/4/2016 | 4/4/2016 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI Rough in ok cover p/s u/g n ok
|