Permit Information
Permit NumberELE16-01333
StatusFinaled
Name L & K ELECTRIC
Site Address 4869 W MALAD ST Unit: D
Project Name 
Customer Number2083751653
ePlanReviewNo
Description
Alteration or Repair: New wiring for x-ray machine
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/19/20167/20/20167/20/2016APASS
DetailsRock A. Hudson
Dr. Blom// please call before Phone #: ###-#### No card posted. Listing confirmed. Final ok
Final5/31/20166/1/20166/1/2016AFAIL
DetailsRock A. Hudson
Hi Rock,
Address and corrections have been made. Final inspection please. Contact is David Joseph ###-####. Please call if you have any questions as David will not be on the job site or you can call the office ###-####. Phone #: ###-#### Inspection requested via web by Laura Longshaw
Wiring from disconnecting means to x-ray equipment shall be inspected and listing shall be checked.
110.26- Disconnect shall have 30" wide and 36" deep minimum work space in front.
-Dedicated electrical space shall be provided from floor to ceiling width and depth of fused electrical disconnect.
Permanent Service5/31/20166/1/20166/1/2016APASS
DetailsRock A. Hudson
Hi Rock,
Permanent Service final inspection please. David Joseph in your contact ###-####. Please call if you have any questions as he will not be on the job site. You can also call the office if you have any questions ###-####.
Thank you for everything and have an awesome day. Phone #: ###-#### Inspection requested via web by Laura Longshaw
2nd meter for space D. p/s u/g n ok
Final5/31/20165/31/20165/31/2016PFAIL
DetailsRock A. Hudson
Sorry for the trouble on this one. Please do a final inspection on Suite D. Contact is David Joseph ###-####. Please let me know if there is any trouble getting in. We appreciate you. Phone #: ###-#### Inspection requested via web by Laura Longshaw
230.70(B)- Service disconnecting means shall be as to which unit it feeds. Marked unit C.
250.24(A)(5)- Grounded conductor shall ot be connected to non- current carrying metal parts, to equipment grounding conductor, lor to ground on load side of service disconnecting means.
* Permanent service inspection required.
* X-ray equipment shall be set to check listing of equipment prior to final inspection.
* Correct address shall be on permit.
Final5/27/20165/27/20165/27/2016PNH
DetailsRock A. Hudson
Final for this project. Future for X-Ray machine. Contact is David Joseph ###-####. Please call if you have any questions as David will not be on site. Thank you and have a super weekend. Phone #: ###-#### Inspection requested via web by Laura Longshaw
Doors locked called left message
Final5/23/20165/24/20165/24/2016PCANC
DetailsRock A. Hudson
Final please. Contact is David Joseph ###-####. Please give him a call if you have any questions as he will not be on the job site. Thank you again and have a super day! Phone #: ###-#### >> Inspection requested via web by Laura Longshaw Inspection cancelled from web by: Laura Longshaw
Permanent Service5/23/20165/24/20165/24/2016PCANC
DetailsRock A. Hudson
Permanent Service inspection please. (It is for a future possible X-Ray machine.) Contact is David Joseph ###-####. Please give him a call if you have any questions as he will not be on the job site. Thank you and have a super day! Phone #: ###-#### >> Inspection requested via web by Laura Longshaw Inspection cancelled from web by: Laura Longshaw
Permanent Service5/23/20165/24/20165/23/2016ACANC
DetailsRock A. Hudson
Permanent service final. Contact is David Joseph ###-####. Please call him if you have any questions as he will not be on site. Thank you and have a great day! Phone #: ###-#### >> Inspection requested via web by Laura Longshaw Inspection cancelled from web by: Laura Longshaw
Final5/23/20165/24/20165/23/2016ACANC
DetailsRock A. Hudson
Its final time. Contact is David Joseph ###-####. Please call him with any questions as he will not be on site. Thank you and have a great day! Phone #: ###-#### >> Inspection requested via web by Laura Longshaw Inspection cancelled from web by: Laura Longshaw
Electrical Rough-In4/27/20164/28/20164/28/2016PCANC
DetailsRex Boyles
Wall rough-in inspection please. Contact is David Joseph ###-####. Please give him a call if you have any questions as he will not be on site. Thank you and have a super day! Phone #: ###-#### >> Inspection requested via web by Laura Longshaw Inspection cancelled from web by: Laura Longshaw
Electrical Rough-In4/27/20164/27/20164/27/2016PCANC
DetailsRex Boyles
Wall rough-in inspection please. Contact will be David Joseph ###-####. If he does not answer his phone due to any questions you may have please call Laura at ###-#### as David will be in an Idaho Power class starting at 12:30 today.Thank you so much and have a wonderful day. Phone #: ###-#### >> Inspection requested via web by Laura Longshaw Inspection cancelled from web by: Laura Longshaw