Permit Information
Permit NumberELE16-01579
StatusFinaled
Name SUBLIME ELECTRIC LLC
Site Address 1306 S MANITOU AVE
Project Name 
Customer NumberCook
ePlanReviewNo
Description
Complete Installation (includes room count and per: Wiring new duplex
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/13/201612/14/201612/14/2016APASS
DetailsJames Ady
The key is inside the front porch outlet cover. Any questions please call Luke ###-#### Phone #: ###-#### Inspection requested via web by Clay Morgan Corrections made Final ok
Final12/12/201612/12/201612/12/2016PFAIL
DetailsJames Ady
Key is inside the front porch outlet cover. Any questions please call Luke ###-#### Phone #: ###-#### Inspection requested via web by Clay Morgan Unit 101. 210.52 C 1 No part along wall line shall be more than 24in. (left of cook top) 110.3 B Listed material shall be installed according to manufacturer Specs. (Up back bed, Reverse polarity, Weatherproof by A/C not working. Unit 102 110.3 B Front weather proof. Bottom Screw falling out. Both Units Back patio lights will not turn on. Verify lights have a photo cell of fix problem
Permanent Service12/8/201612/8/201612/8/2016PPASS
DetailsJames Ady
Please call Luke if you have any questions. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan p/s u/g rec ok
Final11/16/201611/17/201611/17/2016AFAIL
DetailsJames Ady
The key is in the front door weatherproof Cover Phone #: ###-#### Inspection requested via web by Clay Morgan Need to get permit straightened out.
Electrical Rough-In9/2/20169/2/20169/2/2016PPASS
DetailsJames Ady
If you have any questions, please call Clay. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Undergroung to garage ok to cover
Electrical Rough-In9/1/20169/1/20169/1/2016PFAIL
DetailsJames Ady
Underground. If you have any questions, please call Clay ###-####. Thank you!! Phone #: ###-#### Inspection requested via web by Clay Morgan 352.48 joint shall be made by an approved method. (No joints are glued)
Electrical Rough-In8/31/20169/1/20169/1/2016ANR
DetailsBob Reichert
Its underground from house to garage. Phone #: ###-#### Inspection requested via web by Clay Morgan called, told contractor BLD calls for duplex, so only 1 service allowed, 2 meters, not a service on each side of structure, will check and recall
Rough-In Permanent Service6/2/20166/3/20166/3/2016APASS
DetailsJames Ady
Someone should be there, if you have any questions, please call Mike at ###-####. Thank You!! Phone #: ###-#### Inspection requested via web by Clay Morgan Corrections made Rough in ok. p/s u/h n ok
Rough-In Permanent Service6/1/20166/2/20166/2/2016AFAIL
DetailsEric Story
If you have any questions, please call Mike at ###-####. Thank You! Phone #: ###-#### Inspection requested via web by Clay Morgan
210.52 receptacles shall installed within 6' of a door opening
300.4 borded holes that dont maintain 1 1/4" from framing member shall a listed nailplate
Need to verify u/g or o/h feeds(discussed with insulation company on not insulating proir to electrical or all inspections)