Permit Information
Permit NumberELE16-01732
StatusFinaled
Name SUBLIME ELECTRIC LLC
Site Address 3400 W CASSIA ST
Project Name 
Customer NumberLevco
ePlanReviewNo
Description
Alteration or Repair: Kitchen, bathroom and living room remodel
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/5/20168/5/20168/5/2016PPASS
DetailsEric Story
as per James Ady final ok
Final8/4/20168/4/20168/4/2016PFAIL
DetailsEric Story
If you have any questions, please call Jared ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan
314.20 recessed boxes in combustable material shall have a listed extender(back west room)
406.6 faceplates missing (master bath&west back room)
406.6(d)(2) GFCI protection for non grounded outlets(west back room , can not locate the GFCI)
Final8/2/20168/2/20168/2/2016PFAIL
DetailsJames Ady
If you have any questions, please call Jared at ###-####. Thank you!! Phone #: ###-#### Inspection requested via web by Clay Morgan 406.4 D (2) c Non grounded receps shall be marked GFCI Protected AND No equipment ground. 210.12 AFCI protection required in all bedrooms. Master bed. Master bath recep East wall doesnt work.
Electrical Rough-In6/2/20166/2/20166/2/2016PPASS
DetailsJames Ady
If you have any questions, please call Jared at ###-####. Thank you!! Phone #: ###-#### Inspection requested via web by Clay Morgan Corrections made rough in ok to cover
Electrical Rough-In5/31/20166/1/20166/2/2016AFAIL
DetailsRock A. Hudson
There should be someone there. If you have any questions, please call Jared at ###-####, thank you!! Phone #: ###-#### Inspection requested via web by Clay Morgan
314.23- Boxes shall be secured. 2 boxes in master bed and bath hanging on wire.
314.29- All boxes shall be accessible. Box to left of fireplace appears to have no access when rocked.