Permit Information
Permit NumberELE16-03412
StatusFinaled
Name ALLOWAY ELECTRIC CO INC
Site Address 101 S CAPITOL BLVD Unit: 900
Project NameSTOLTZ MARKETING GROUP
Customer Number72516
ePlanReviewNo
Description
Alteration: 9th Floor Stoltz TI
1) Demo as required per print.
2) Provide receptacles as required per print.
3) Provide and install data drop to accessible ceiling per print.
4) Provide and install two floor two floor boxes owner provided
including core drillin
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/9/20172/10/20172/10/2017PPASS
DetailsRock A. Hudson
9th floor correction inspection Phone #: ###-#### Inspection requested via web by steve ragan Final ok
Final2/7/20172/8/20172/8/2017PFAIL
DetailsRock A. Hudson
9th floor Phone #: ###-#### Inspection requested via web by steve ragan
BCC 4-05-32- Code violations not to be retained. Repair existing MC and metal flex that had been installed above old grid without being supported.
330.30- Existing MC shall have supports not to exceed 6'.
348.30- Metal flex used to feed upper unit has broken interlock and shall have supports not to exceed 4 1/2'.
410.20- Luminaire outlet and cover shall provide room for conductors being installed. Canopy held down so would not pinch flexible cord of luminaire at mud ring. Canopy shall completely enclose outlet opening.
Final2/7/20172/8/20172/7/2017ACANC
DetailsRock A. Hudson
9th floor TI Phone #: ###-#### >> Inspection requested via web by steve ragan Inspection cancelled from web by: steve ragan
Electrical Rough-In12/15/201612/16/201612/16/2016APASS
DetailsRock A. Hudson
Rough-in data and receptacle boxes/conduit in newly extended wall. Light box in conference room ceiling Phone #: ###-#### Inspection requested via web by steve ragan
Conference room hardlid and wall rough in ok cover
Electrical Rough-In11/16/201611/17/201611/17/2016APASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by steve ragan
South out of elevator. TI is south east corner of floor. Wall rough in ok cover
Electrical Rough-In10/20/201610/21/201610/21/2016AFAIL
DetailsRock A. Hudson
Inspection requested via web by steve ragan
BLD16-03684 is still under review and ELE permit shall be attached to BLD when issued.