Final | 12/1/2016 | 12/1/2016 | 12/1/2016 | P | PASS |
Eric Story
|
|
|
Paul Phone #: ###-#### service change final ok
|
Permanent Service | 11/30/2016 | 11/30/2016 | 11/30/2016 | P | PASS |
Eric Story
|
|
|
p/s o/h rec ok
|
Final | 11/29/2016 | 11/30/2016 | 11/30/2016 | A | PASS |
Eric Story
|
|
|
off over 1 year Phone #: ###-#### p/s o/h rec ok
|
Final | 11/14/2016 | 11/15/2016 | 11/15/2016 | P | CANC |
Eric Story
|
|
|
would like call ahead; Paul Phone #: ###-#### Needed conference
|
Conference | 11/15/2016 | 11/15/2016 | 11/15/2016 | P | DONE |
Eric Story
|
|
|
would like call ahead; Paul Phone #: ###-#### Discussed redoing service, there is no disconnecting means on exterior of building all unfused going to house panel. Homeowner will replace with a meter main ,upgrade groung electrode system, will seperate grounds and neutrals. Metal conduit will remain and existing feeders, will use ground bushing at both ends for equipment grounding to panel.
|