Permit Information
Permit NumberELE16-04108
StatusFinaled
Name LEA ELECTRIC LLC
Site Address 1401 S LUSK PL
Project Name 
Customer Number3618
ePlanReviewNo
Description
Alteration: Electrical demolition and installation of wiring, lights, fixtures, receptacles, panels and boxes, and gatehouse building.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/6/20176/7/20176/7/2017APASS
DetailsRock A. Hudson
Final Inspection on the Gatehouse
Contact Dan Hutchinson
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Final ok
Final6/1/20176/1/20176/1/2017PPART
DetailsRock A. Hudson
Final Inspection for the Gatehouse
Contact Dan Hutchinson
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek
Need complete upstairs lighting, underground for sign and pole lights deeper, receptacle with in 25' of HVAC units north side of building ground level, secure out conduits and disconnects on north side. TCO ok
Final5/30/20175/31/20175/31/2017PFAIL
DetailsRock A. Hudson
Final Inspection for Gatehouse
Contact Dan Hutchinson
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek
BCC 4-05-32 Code violations not to be retained. While residing existing portion conduit supports removed. All MC shall be protected from physical damage and supported as per NEC.
210.8- GFCI protection for drinking fountain shall be installed at a readily accessible location.
210.63- Service receptacles shall be installed with in 25' of AC equpment.
210.64- Service receptacle shall be installed with in 50' of electric service.
IBC- Emergency egress lighting providing 1 ft/candle of light shall be provided at exterior of each exit.
Electrical Rough-In5/24/20175/24/20175/24/2017APASS
DetailsMark Moncarr
Ceiling Inspection in the Gatehouse.
Contact Dan Hutchinson ###-####
Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Ok cover ceiling in food prep area
Electrical Rough-In5/17/20175/18/20175/18/2017APASS
DetailsEric Story
Ceiling Inspection at the Gatehouse
Contact Dan Hutchinson
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek
Suspended ceiling above reception desk and heater wall in riser room ok cover
Electrical Rough-In5/8/20175/9/20175/9/2017PPASS
DetailsEric Story
Underground Inspection for in front of Gatehouse.
Contact Dan Hutchinson
Thank you. Phone #: ###-#### Inspection requested via web by Cathy Duchek
u/g for sign and gate ok cover
Electrical Rough-In4/5/20174/6/20174/6/2017PPASS
DetailsRock A. Hudson
Rough-In Inspection for the gatehouse
Contact Dan Hutchinson
Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek
Walls and hardlids rough in ok cover
Electrical Rough-In3/16/20173/17/20173/17/2017APASS
DetailsRock A. Hudson
Underground Inspection on the Gatehouse.
Contact Dan Hutchinson
Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek
Underground must be under concrete due to 12" depth. Rough in ok cover
Permanent Service3/7/20173/7/20173/7/2017APASS
DetailsTom Saunders
Service Inspection
Contact Dan Hutchinson
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek...

p/s u/g rec ok
Conference1/27/20171/27/20171/27/2017PDONE
DetailsEric Story
Discussed service change and relocation of CT can, overcurrent device and main discconect will be on outsideof building due to unfused conductors ran inside building and not encased in concrete
Electrical Rough-In12/23/201612/23/201612/23/2016PPASS
DetailsRock A. Hudson
Uffer ground inspection
Contact Tom Betty Phone #: ###-#### Inspection requested via web by Cathy Duchek
Concrete encased electode rough in ok cover