Final | 2/19/2017 | 2/24/2017 | 2/24/2017 | A | PASS |
Rock A. Hudson
|
|
|
As early as possible Phone #: 2088411007 >> Inspection requested via mobile web by Matt Frey Final ok
|
Conference | 1/17/2017 | 1/18/2017 | 1/18/2017 | A | DONE |
Rock A. Hudson
|
|
|
Please call ahead for access - Matthew Phone #: ###-#### or Krista ###-#### Discussed addition of AC unit to east side of house. Water heater changing to gas. Will junction 30 amp circuit in basement and run out to east side. Basement ceiling open will call for final when complete all will be visible. Disconnecting means shall be with in sight and with in 50', service receptacle added with in 25' and shall be tamper and weather resistant type. Holes in boxes shall have abrasion protection and NM cable shall have supports not exceeding 4 1/2' and 12" of box.
|