Final | 9/27/2017 | 9/28/2017 | 9/28/2017 | A | PASS |
James Ady
|
|
|
Al Phone #: ###-#### Final ok
|
Electrical Rough-In | 8/24/2017 | 8/25/2017 | 8/25/2017 | A | PASS |
James Ady
|
|
|
Al Phone #: ###-#### Corrections made rough in ok
|
Electrical Rough-In | 8/23/2017 | 8/24/2017 | 8/24/2017 | A | FAIL |
James Ady
|
|
|
Al Baun Phone #: ###-#### Pig tail grnds, Main disc. in panel, Overfilled box in garage, Re-staple romex that has been stapled on edge.
|
Electrical Rough-In | 4/11/2017 | 4/11/2017 | 4/11/2017 | P | PASS |
Eric Story
|
|
|
Al Phone #: ###-#### u/g from house to shop ok cover
|
Conference | 3/15/2017 | 3/15/2017 | 3/15/2017 | P | DONE |
Rock A. Hudson
|
|
|
Tammy Phone #: ###-#### Discussed wiring a detached garge/shop. Main service will be on shop and 200 amp feed thru to refeed house. Discussed conduit depth 18", tamper receptacles, GFCI protection of garage, within 6' of sink, WR, GFCI, TR outdoor receptacles. Various wire sizes, overhead service entrance clearance over alley. Grounding of service to have concrete encased and grounding of panel at detached house to have underground water pipe and ground rod added.
|