Final | 6/22/2017 | 6/22/2017 | 6/22/2017 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks Corrections made Final ok
|
Final | 6/19/2017 | 6/19/2017 | 6/20/2017 | P | FAIL |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks 406.12 All receps in a dwelling shall be Tamper resistan.( Island, cooktop, Up S.W bed next to door.) 410.16 B Open lamps shall not be installed in closet (Master, & front bed) 410.16 C Recessed light shall be 6in from front edge of closet shelf. (Down front bed) 210.8 All receps within 6ft of a sink shall be GFCI protected. (Washer) 110.7 Wireing shall be free of shorts.(Down Living room. 210.12 Dwelling bedrooms shall be AFCI protected. (Down bed) 314.20 Flush mounted boxes set back more than 1/4in. Back splash boxes shall be pulled out flush with tile. 210.52 A 2 Receps shall be within 6ft of a door. (Next to solid panel on rear slider) (Missing powder bath fan) (front down bed receps dead)
|
Electrical Rough-In | 6/13/2017 | 6/13/2017 | 6/13/2017 | P | NR |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks Wrong job called in
|
Rough-In Permanent Service | 3/30/2017 | 3/30/2017 | 3/30/2017 | A | PASS |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks Rough-in ok cover p/s u/g n ok
|
Rough-In Permanent Service | 3/29/2017 | 3/29/2017 | 3/29/2017 | P | FAIL |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks 210.52 G1 The baranch circuit supplying required garage recep shall have no other outlets. 250.68 A All mechanical elements used to terminate grounding electrode shall be accessible. 250.148. Continuity of grounding conductors.( Smoke detectors)
|