Final | 7/27/2017 | 7/27/2017 | 7/27/2017 | A | PASS |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by Matthew Hansen Corrections fixed final ok
|
Final | 6/27/2017 | 6/28/2017 | 6/28/2017 | A | FAIL |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by Matthew Hansen Bathroom receptacle shall be tamper resistant All receptacles shall be GFCI protected in a kitchen
|
Electrical Rough-In | 4/19/2017 | 4/20/2017 | 4/20/2017 | A | PASS |
Eric Story
|
|
|
We had an electrician pull a separate permit to address the issue of power for the kitchen island. Bathroom addition is on a dedicated 20 amp circuit. Will provide visual access to wiring in bathroom addition to verify that wiring has been properly secured inside the wall. Phone #: ###-#### Inspection requested via web by Matthew Hansen Homeowner cut holes in sheetrock to verify support of wires and wire size. Electrician that wired island will need to pull a permit and final it out when job is complete. Notice no insulation in walls adjacent to garage did warn homeowner it needed it.
|
Conference | 4/13/2017 | 4/18/2017 | 4/18/2017 | A | DONE |
Eric Story
|
|
|
Please meet to discuss scope of work. Thank you! Phone #: ###-#### Inspection requested via web by Matthew Hansen Discussed drilling holes in bath to verify wiring and to sure bath receptalce is 20 amp dedicated, Island will be on casters to get away from island outlet to be GFCI or 2 wire receptacles and tamper resistant type
|