Permit Information
Permit NumberELE17-02099
StatusFinaled
Name SANGREY HARLAN D
Site Address 615 N POND ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/26/201712/26/201712/26/2017PPASS
DetailsEric Story
Harlan Phone #: ###-####
Final ok
Electrical Rough-In11/14/201711/15/201711/15/2017APASS
DetailsRock A. Hudson
Harlan Phone #: ###-####
Horizontal runs located at back of garage not covered and shall be covered for final. Rough in ok cover
Electrical Rough-In11/13/201711/13/201711/13/2017PFAIL
DetailsRock A. Hudson
Harlan Phone #: ###-####
110.27(A)(4)(a)- Electrical equipment located below 8' from floor shall be protected from physical damage. All wiring located below 8'.
250.148- All equipment grounding conductors located in a box shall be connected together by approved means. 2 gang by man door.
352.30- PVC shall be secured in place with in 3' of a box or conduit body. Secure below house service and garage panel.
Electrical Rough-In9/11/20179/11/20179/11/2017PPASS
DetailsRock A. Hudson
Harlan Phone #: ###-####
Underground from house to garage rough in ok cover
Conference8/23/20178/23/20178/23/2017PDONE
DetailsRock A. Hudson
Harlan-please call 15 minutes prior to meet Phone #: ###-####
Discussed wiring for detached garage with unfinished walls and 100amp feed.
1 outdoor light at each man door controlled by switch or automatic means, minimum of 2 receptacles for car bays for depth, all 120 volt receptacle outlets shal be 20 amp, tamper resistant, GFCI protected and wiring shall be protected from physical damage by wiring meathod or framing if MN cable. Minimum of #4 for garage feeders with #6 ground and 2 ground rods at garage. Depth of underground shall be 18" for conduit or 24" for cable.