Final | 10/11/2017 | 10/12/2017 | 10/12/2017 | A | PASS |
James Ady
|
|
|
garage code 1424 Phone #: ###-#### Inspection requested via web by Darryn Coburn Corrections made final ok
|
Final | 10/6/2017 | 10/6/2017 | 10/6/2017 | P | FAIL |
James Ady
|
|
|
Garage code is 1424 Phone #: ###-#### Inspection requested via web by Darryn Coburn 210.52 Bath recep shall be on adjacent wall.( Master bath vanity) All 3 w/p receps are dead. Switched power Spare bed closet. 3way common mixed up on Bar hall lights. Travelers for garage and mud room lights mixed up.
|
Final | 7/18/2017 | 7/19/2017 | 7/19/2017 | A | NR |
Rock A. Hudson
|
|
|
garage code 0324 Phone #: ###-#### Inspection requested via web by Darryn Coburn rough in done on 7-17-17. requested wrong job.
|
Rough-In Permanent Service | 7/14/2017 | 7/17/2017 | 7/17/2017 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Interior only, soffit cans fire barriers not done. Rough in ok cover p/s u/g n ok
|