Final | 7/24/2018 | 7/25/2018 | 7/25/2018 | A | PASS |
Rock A. Hudson
|
|
|
Call Mike Cole with any questions Phone #: ###-#### Inspection requested via web by Bonnie Page Final ok
|
Final | 7/24/2018 | 7/24/2018 | 7/24/2018 | P | FAIL |
Rock A. Hudson
|
|
|
Call Mike with questions, he should be at the house. Phone #: ###-#### Inspection requested via web by Bonnie Page 210.8- Receptacles located with in 6' of kitchen sink shall have GFCI protection. 210.8- Receptacles located in bathrooms shall have GFCI protection, up bath stool. 314.25- All boxes shall have covers in place. 408.4- Panels circuit directories shall be complete.
|
Permanent Service | 4/10/2018 | 4/11/2018 | 4/11/2018 | A | PASS |
Rock A. Hudson
|
|
|
Please contact Mike Cole ###-#### Inspection requested via web by Bonnie Page p/s u/g rec ok
|
Electrical Rough-In | 2/15/2018 | 2/16/2018 | 2/16/2018 | A | CANC |
Rock A. Hudson
|
|
|
Grounding Inspection. Call Mike Cole ###-#### Phone #: ###-#### Inspection requested via web by Bonnie Page duplicate request see RI 2-15-18
|
Electrical Rough-In | 2/15/2018 | 2/15/2018 | 2/15/2018 | P | PASS |
Rock A. Hudson
|
|
|
Ground rods on north side near conduits for service to be buried under pavers. Rough in ok cover
|
Electrical Rough-In | 1/25/2018 | 1/25/2018 | 1/25/2018 | P | PASS |
Rock A. Hudson
|
|
|
Mike Phone #: ###-#### West family room and powder bath rough in ok cover
|
Electrical Rough-In | 12/7/2017 | 12/7/2017 | 12/7/2017 | P | PASS |
Rock A. Hudson
|
|
|
Rock I need to be there to meet you so i will work my lunch around you if need be. I leave for day at 3:30 ish. Mike Phone #: ###-#### Inspection requested via web by Mike Cole North family rm ok, formal dining not walls open, Main family rm no open walls, piano rm ok, entry ok, guest bed and bath ok, master bed and bath ok, all upstairs ok. Some circuits ungrounded. Areas noted rough in ok cover
|
Electrical Rough-In | 10/16/2017 | 10/16/2017 | 10/16/2017 | P | PASS |
Rock A. Hudson
|
|
|
PANIO ROOM, ENTRY AND SECOND FLOOR Inspection requested via web by Mike Cole Entrance, piano room, upstairs beds and bathrooms rough in ok cover
|
Conference | 10/16/2017 | 10/16/2017 | 10/16/2017 | P | DONE |
Rock A. Hudson
|
|
|
PANIO ROOM, ENTRY AND SECOND FLOOR Inspection requested via web by Mike Cole Discussed with contact electrical service for residence. Existing meter located on power pole near road with underground to main breaker panel located in garage. BCC 4-05-32 No code violation shall be retained. BCC 4-05-31 Unfused conductors shall not enter building or structure. 230.70- Service disconnecting means shall be located on exterior of building or immediately adjacent to entrance of service entrance conductors.
|
Electrical Rough-In | 7/20/2017 | 7/20/2017 | 7/20/2017 | P | PASS |
Rock A. Hudson
|
|
|
GUEST BED, HALL AND BATH. GO IN FRONT DOOR TURN RIGHT THRU PLASTIC HOME OWNER WILL MEET YOU CALL MIKE COLE 20 MINUTES LEAD TIME AND I WILL CALL HOME OWNER Phone #: ###-#### Inspection requested via web by Mike Cole Guest bed walls not opened up, all wiring ungrounded. New circuit for bath receptacle in 4 gang. Rough in ok cover
|