Permit Information
Permit NumberELE17-02310
StatusIssued
Name COPPERHEAD ELECTRIC
Site Address 7402 W WESTWOOD DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: Replace main service and sub panel.
Rough in enclosed porch.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
ELE-Aging Inspection6/30/20206/30/20206/30/2020 PEND
DetailsDaryl DeGrange
The permit is still open with the City of Boise. Please call 208 ###-#### with progress report or any questions. If your job is complete, please schedule an final inspection online. Thank you!
ELE-Aging Inspection3/31/20203/31/20204/1/2020 DONE
DetailsTom Saunders
texted info to contractor
permit number and corrections
4/1/20 11AM
ELE-Aging Inspection12/31/201912/31/201912/31/2019 DONE
DetailsTom Saunders
message been sent to contact
making aware of corrections need made and inspection scheduled
ELE-Aging Inspection9/20/20199/20/20199/20/2019 FAIL
DetailsTom Saunders
contractor is aware and making no attempt to make corrections and schedule inspections
ELE-Aging Inspection6/21/20196/21/20196/21/2019 FAIL
DetailsTom Saunders
contractor needs to schedule final
corrections need made immediately
Final12/18/201712/18/201712/18/2017PFAIL
DetailsRock A. Hudson
Homeowner will be available 2 walkthrough. Phone #: ###-#### Inspection requested via web by Casey Fouts
210.8- All garage 120 volt receptacles shall have GFCI protection. Garage refrigerator.
406.6- Old receptacle in brick in craft room is a grounded type receptacle on a ungrounded circuit. Blank, change to 2 wire receptacle or GFCI protect grounding type receptacle. No code violation shall be retained.
408.4- Circuit directory shall be complete on sub panel and service panel.
Electrical Rough-In7/20/20177/21/20177/21/2017PPASS
DetailsTom Saunders
Please call 30min in advance so that I can meet the inspector. Phone #: ###-#### Inspection requested via web by Casey Fouts...

addition ok to cover
Permanent Service7/19/20177/20/20177/20/2017APASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Casey Fouts
p/s o/h rec ok