Final | 10/18/2017 | 10/18/2017 | 10/18/2017 | A | PASS |
Rock A. Hudson
|
|
|
Please call for access. ###-#### Phone #: ###-#### Inspection requested via web by Kevin Perez Final ok
|
Final | 10/16/2017 | 10/16/2017 | 10/16/2017 | P | FAIL |
Rock A. Hudson
|
|
|
Please call for access. ###-#### Thanks Phone #: ###-#### Inspection requested via web by Kevin Perez 110.3- Open ground shown on receptacle on back of kichen pass thru wall. 210.52(C)(1)- No point along kitchen counter surface measured along wall line shall be more than 24" from a receptacle outlet. Due to limited space receptacle outlet OK under overhang if compliant with 210.52(C)(5) exception to 5.
|
Final | 10/13/2017 | 10/16/2017 | 10/16/2017 | A | CANC |
James Ady
|
|
|
Please call for access code to lock box. Phone #: ###-#### >> Inspection requested via web by Kevin Perez Inspection cancelled from web by: Kevin Perez
|
Electrical Rough-In | 8/23/2017 | 8/25/2017 | 8/25/2017 | P | PASS |
Rock A. Hudson
|
|
|
Please call with any items. Access code is 6977 for lock box. Phone #: ###-#### Inspection Spoke with contact, master bath vanity receptacle and circuit, closet switch and light, bath fan not in at time of inspection. Drywall still on walls, will be fished in by final. Electrical openings not use will be abandonded. Lower kitchen cabinets removed GFCI protection required for counter top. Rough in ok cover
|