Information based on query as of Sunday, June 30, 2024.
Permit Information
Permit NumberELE17-02801
StatusFinaled
Name ECO ELECTRIC
Site Address 1202 E SHAW MOUNTAIN RD
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: Added canned lights, light fixtures, switches, outlets & circuit
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/28/201712/28/201712/28/2017APASS
DetailsMark Moncarr
Phone #: ###-#### Inspection requested via web by Eric Schroeder Ok final. Corrections made.
Final12/21/201712/22/201712/22/2017AFAIL
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Eric Schroeder 210.52A2 Wall spaces greater than2ft shall hve recep. (master bed under 3 gang). 210.51D At least 1 recep shall be installed within 36in of sink basin. Recep shall be on adjacent wall. ( Master vanity) Exposed romex on either side of fireplace needs safed off, put in j-boxes.
Electrical Rough-In8/30/20178/31/20178/31/2017APASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Eric Schroeder Dining, Kitchen, loft, Bath and Mud room only. Corrections made ok to cover
Electrical Rough-In8/25/20178/25/20178/25/2017PFAIL
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Eric Schroeder 210.52B2 Nook and dining shall be part of the 2 or more small appliance circuits. 210.52A2 Wall space, Loft, Shall have recep within 6ft of hand rail