Final | 12/7/2017 | 12/7/2017 | 12/7/2017 | P | PASS |
Rock A. Hudson
|
|
|
Ron Phone #: ###-#### Final ok
|
Final | 12/5/2017 | 12/6/2017 | 12/6/2017 | A | FAIL |
Rock A. Hudson
|
|
|
Ron Phone #: ###-#### 210.8- All 120 volt receptacle outlets located in unfinished basement areas shall have GFCI protection. Recept. to left of panel. 250.32- Seperate building grounding electrode system, underground metal water pipe shall be supplemented by additional rod or pipe as per 250.53(A)(2). As per conversation with 345 issue discussed on rough in and equipment ground and underground metal water pipe all required. Disregard supplemental at house panel. 300.4- NM cable where enters enclosure shall have abrasion protection. 12-2 back of service panel. 408.4- Label garage circuit.
|
Electrical Rough-In | 10/26/2017 | 10/27/2017 | 10/27/2017 | A | PASS |
James Ady
|
|
|
Jon (owner; but Ron called it in) Phone #: ###-#### bath only rough in ok
|
Electrical Rough-In | 9/25/2017 | 9/25/2017 | 9/25/2017 | P | PASS |
Eric Story
|
|
|
Please call for access and to meet, Bacon St. 1st, then Bannock - Ron Phone #: ###-#### Whole houise ok to cover
|
Electrical Rough-In | 9/5/2017 | 9/6/2017 | 9/6/2017 | A | PASS |
Eric Story
|
|
|
underground-Ron Phone #: ###-#### Underground to house from ok cover
|
Permanent Service | 9/6/2017 | 9/6/2017 | 9/6/2017 | P | PASS |
Eric Story
|
|
|
underground-Ron Phone #: ###-#### p/s o/h rec ok
|