Final | 11/21/2017 | 11/22/2017 | 11/22/2017 | A | PASS |
Daryl DeGrange
|
|
|
Jason is the contact his cell no is ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates Correction done, final ok
|
Final | 11/20/2017 | 11/21/2017 | 11/21/2017 | A | FAIL |
Rock A. Hudson
|
|
|
Jason is the contact his cell no is ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates 314.25- All boxes shall have covers. box located on patio open. 406.4(D)- Still have grounding type receptacle outlets on ungrounded circuits with out GFCI protection. 406.4(D)- All grounding type receptacles on ungrounded circuits shall be labeled " no equipment ground and GFCI protected".
|
Rough-In Permanent Service | 11/8/2017 | 11/9/2017 | 11/9/2017 | A | PASS |
Rock A. Hudson
|
|
|
Jason is the contact his cell no. is ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates Rough in service moved from enclosed back patio to west side of house ok. Contractor to remove abandoned wiring in crawl space, address all receptacles on ungrounded circuits, add bathroom circuit and kitchen small appliance circuits and flexible cords installed as substitute for building wiring. p/s o/h rec ok
|