Permit Information
Permit NumberELE17-04027
StatusFinaled
Name TREASURE VALLEY ELECTRIC INC
Site Address 801 W BANNOCK ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Addition: Tenant Improvement of existing space.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/28/20183/1/20183/1/2018APASS
DetailsRock A. Hudson
Correction have been made as noted Phone #: ###-#### Inspection requested via web by Steve Craig
Final ok
Final2/25/20182/26/20182/26/2018AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Steve Craig
BCC 4-05-23 It shall be unlawful to cover any wiring or equipment prior to inspection. Kitchen grid installed prior to inspection. Kitchen appliances installed no access to devices.
210.8- All GFCI devices shall be located in a readily accessible location.
210.8(B)- All kitchen receptacles shall have GFCI protection, 1 pole and multi pole receptacles.
300.15- All wiring shall terminate in a box. Sign conduits, above north door, mezz wiring in floor. open box in basement, above grid.
Electrical Rough-In12/27/201712/27/201712/27/2017PPASS
DetailsRock A. Hudson
Cover inspection for new framed walls and existing wall opened to install electrical Phone #: ###-#### Inspection requested via web by Steve Craig
Main level wall rough in ok cover
Conference12/12/201712/13/201712/13/2017ADONE
DetailsRock A. Hudson
Consultation request Phone #: ###-#### Inspection requested via web by Steve Craig
Discussed the required spacing for showroom window receptacles. Asked if maximum space for required receptacles could be increased to mount on columns. 210.62 states max spacing shall not exceed 12'. Shall not exceed 12' spacing between receptacles.
Conference11/30/201711/30/201711/30/2017PDONE
DetailsRock A. Hudson
Call 1 hour prior to confirm Phone #: ###-#### Inspection requested via web by Steve Craig
Discussed if boxes permitted above decorative drop partial ceiling. Wood panels will be small and removeable, box access ok above. Also showroom window receptacles may be few inches over 18" due to structural steel beam. OK. Asked about required emergency and egress lighting informed all depends on occupancy load and to check with life/safety inspector.