Permit Information
Permit NumberELE17-04345
StatusFinaled
Name CANYON ELECTRIC
Site Address 6302 S SCOTCH WAY
Project Name 
Customer Number179610
ePlanReviewNo
Description
Alteration or Repair: Spa Connection & Circuit
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/29/20187/2/20187/2/2018PPASS
DetailsJames Ady
Jeff Phone #: ###-#### Corrections made final ok
Final2/27/20183/1/20183/1/2018ANH
DetailsEric Story
Any questions please call Louis at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller
No body home
Final2/6/20182/12/20182/12/2018AFAIL
DetailsJames Ady
Any questions please call louis at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller 334.12(B)(4)- NM cables shall not be installed In wet or damp locations. Inside outdoor or underground raceways concidered wet location
Final12/28/201712/29/201712/29/2017PFAIL
DetailsRock A. Hudson
Any questions please call Louis at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller
300.4(B)(1)- Nonmetallic-Sheathed Cable. In both exposed and concealed locations where nonmetallic-sheathed cables pass
through either factory- or field-punched, cut, or drilled slots or holes in metal members, the cable shall be protected by listed
bushings or listed grommets covering all metal edges that are securely fastened in the opening prior to installation of the
cable. Where NM enters panel.
334.12(B)(4)- NM cables shall not be installed In wet or damp locations. Inside outdoor or underground raceways concidered wet location
Owner had to leave, put correction on meter base.